95X
Series Hipot Testers
Power & Versatility
for your Most Demanding Electrical Safety Test Applications
Vitrek built the 95X Series from
the ground up with DSP technology – to bring you the safest, fastest, most
capable, feature rich hipot testers available. The 95X Series combines high output power, with a wide range
of AC & DC voltage outputs and extremely low leakage current measurement.
Then we added a 4-wire milli-ohmmeter with dynamic range up to 100K ohms and an
overlapping Tera-ohm class Insulation Resistance function. Top that off with an
available 40 Amp Ground Bond capability and you’re just beginning to get a feel
for what the Vitrek 95X Series Hipot Testers can
do for you.
More Speed, More Power, Better Resolution,
More Functionality
What more could you want in an Electrical Safety Tester?
Vitrek 95X Series Hipot Testers
For more than 25 years Vitrek has been driven by an obsession to build a better hipot tester. Increased user safety, faster test times, higher output voltages and
more functionality have been our driving force. The 95X series is
the result of this pursuit – offering power, speed, accuracy and resolution that leave the others far behind.
For Demanding Hipot Tests – Demand the Vitrek 95X
Speed and power go hand in
hand, the 6.5KVDC models offer 50mA of source current for DC Hipot – providing the power you need to rapidly charge and discharge challenging DUTs.
Models are also available with DC hipot up to 11KV
and 15KV. Most of the 95x series also offer 50mA of sourcing for AC hipot,
but for heavier AC loads the 95X can be configured to source up to 100mA or
even as much as 200mA. For higher AC hipot voltages the
95X can generate up to 10KV internally and all models are available with an
external 30KVAC hipot option.
When it comes to making
critical leakage current measurements, the 95X delivers rock-solid resolution
down to 100 pico-amps. This high resolution provides built-in insulation
resistance measurement (IR) up to a Tera-ohm, add a 4-wire milli-ohmmeter with autoranging up to 100K ohm and an available 40 amp Ground Bond function – and you are beginning to understand the versatility of
the Vitrek 95X Series.
Need To Hipot Multiple Test Points?
The 95X has the ability to directly control up to four 64 channel HV scanners, right
out of the box. That is up to 256 test points and using a PC with Vitrek’s QuickTest Pro software you can expand the count up to 640
test points. The HV Switching System of choice is the Vitrek 964i which can hold eight 8 channel switching cards – available in 7, 10 &
15 KV ratings. The 964i also has switching cards to handle routing up to 40 amp ground bond currents.
Capabilities |
951i |
952i |
953i |
954i |
955i |
957i |
959i |
AC Hipot
(Max Std Current)
(500VA Option)
(2KV Max Option)
(30KVAC Ext. opt) |
20V-6KV
50mA
100mA
200mA
10mA |
20V-6KV
50mA
–
200mA
10mA |
20V-6KV
50mA
100mA
200mA
10mA |
20V-6KV
50mA
–
200mA
10mA |
50V-10KV
30mA
–
–
10mA |
20V-6KV
50mA
100mA
200mA
10mA |
–
–
–
–
– |
DC Hipot / IR
(Max Current)
(Max IR) |
30V-6.5KV
50mA
4T |
30V-6.5KV
50mA
4T |
50V-11KV
30mA
8T |
50V-11KV
30mA
8T |
50V-11KV
30mA
8T |
100V-15KV
10mA
10T |
–
–
– |
40A Ground Bond |
– |
Yes |
– |
Yes |
– |
– |
Yes |
4 Wire Ohmmeter
100µΩ to 149KΩ |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Product Features and Benefits
- Highest Level of
Operator Safety – features include: GFI High
speed shut down for earth ground leakage faults, SFI™ Safety
Fault Interlock – High speed shut down output for interruption of safety
interlock, TLSS™ Test Lead Safety Sense – Clamps DUT chassis near ground by continuously verifying proper connection of test
leads prior to and during HV testing,
Recessed start switch prevents inadvertent actuation
- High Power Output –
means better drive capability and increased test throughout. With up to
50mA of sourcing current for DC hipot the 95X
Series gets heavy duty jobs done fast – available 100mA & 200mA AC
drive tackles even the toughest sourcing requirements
- Wide Range of
built-in Voltage Capabilities – Choose from 6.5KVDC, 11KVDC or 15KVDC and 6KVAC, 10KVAC or up
to 30KV RMS AC with external option
- The Fastest Hipot Testers available – Thanks to our Dual Coldfire®
microprocessors combined with Dual DSPs to provide Ramp rates up to
50KV/second, dwell times as low as 20mS and overall test times as fast as
3mS in optional Flash mode
- Expansive Test
Sequence Memory holds up to 100 tests with up to 100
steps per test. Tests can be selected via front panel, Ethernet, RS232,
Digital I/O or with optional GPIB
- Ground Bond Test
Capability available in three models with output currents
from 100mA to 40Amps RMS and test times from 20mS to 1000 seconds or
longer
- 4-Wire
Milli-Ohmmeter Function provides fast, accurate 5
digit resistance measurements with resolution down to
100µΩ and range up to 100K ohms
- Built-in Phase
Angle Measurement – allows the measurement and display
of both resistive (in-phase) leakage current and reactive (out-of-phase)
leakage current caused by capacitive coupling
- Multi-Dwell
Functionality – permits dwells at different
voltage levels without having to return to zero between test steps –
dramatically simplifying advanced analysis of dielectric properties
- Ramp High/Dwell
Low Current Limits – permits the user to set separate
limits for the ramp and dwell providing faster ramp times and lower
leakage test limits
- Ethernet, RS232,
Digital I/O, USB Printer & Scanner Control – All Standard Interfaces –
Provides the highest level of test automation. GPIB optional
- High Voltage
Scanner Control – up to 256 point switching
capability with available 964i HV Scanners.
Route voltages up to 15KV and currents up to 40A for multi-point hipot and ground bond tests
- Dual Dimensional /
Test Specific / Broadband Arc Detection. Where lesser
testers allow you to set a single, global, amplitude only arc limit – the
technologically advanced 95X Series utilizes time & amplitude based arc limits and uniquely applies them to each desired test
- Pico-Amp Leakage
Measurement insures that
even the lowest leakage current levels are accurately detected and
tera-ohm range IR readings are stable and precise
- Test Specific
Fixture & Cable Compensation – Automatically calibrate out offset errors caused by lead
resistance, fixture capacitance and leakage
- Multi-Mode IR –
Insulation Resistance values up to one Tera-ohm can be obtained with
precision in your choice of 3 IR test modes – end on time, end on pass or
end on fail
- Continuously
Variable IR Test Voltage – Unlike most IR testers which limit
you to 3 or 4 discrete test voltages, the 950i Series allows you to select
the test voltage you need. Starting as low as 20V all the way to 6.5KV,
11KV or 15KVDC
- Capacitance Test
Modes –
For AC & DC hipot and IR
provide tightly controlled charge and discharge profiles for superior
results on critical solar panel tests and other highly capacitive loads
- Light Weight
Switching Power Supply Design – Better reliability, easier on your back. Compare the 8.2 kg
95X to whatever you’ve been using
- 400Hz AC Voltage
Withstand Testing provides aviation frequency specific
test results for a more effective analysis of dielectric properties on
avionic components
- Solar Panel
Testing Simplified – Designed with PV testing in mind,
the 950i Series uses pico-amp resolution to detect minute defects in solar
cells
- 3 Year Extended
Warranty – 1 year standard, total of 3 years extended warranty with registration and annual
factory calibration. Built-in reliability you can count on for years to
come
- Safety Tested per EN 61010-1. EMC compliant to EN 61326-1